www.138139.cn

返回总目录 上一页 目录页 下一页

Maxtor Mod各个文件的具体作用


     Maxtor Mod各个文件的具体作用

  Position number

  (PN), hex

  Module purpose Importance

  1E SRV – calibration adaptive data. A

  21 RCT – adaptive information of data zone on surface. A

  37 U_LIST – firmware zone translator. A

  78 RZTBL – zone table. A

  18 AT_PDL (P-List) – translator part responsible for P-List. A

  1F DISK – drive ID. B

  1B AT_POL (G-List) – growing defects table. B

  39 ROM copy B

  38 First part of microcode overlays B

  4F Second part of microcode overlays B

  95 Alternative DISK used in several Poker/Ardent drives. B

  1D DMCS – translator part responsible for operations’ caching. C

  2F S.M.A.R.T. thresholds. D

  1A SECU – security system module (ATA passwords). D

  30 S.M.A.R.T. attributes. D

  70 S.M.A.R.T. Summary Log. D

  71 S.M.A.R.T. Self-Test Log. D

  63 Copy of S.M.A.R.T. attributes D

  33 HUTIL & HUSR – pivot defects table. E

  72 S.M.A.R.T. Host Vendor Log E

  34 RAER_H00 E

  64 MAXATG E

  5E EVTLG_00 E

  7B FWA E

  11 MX_ST_CFG1 E

  43 MX_ST_CFG2 E

  0D MX_ST_CFG3 E

  0E MX_ST_script E

  22 Various settings (flags) E

  7A U_LIST – copy of firmware zone translator E

  83 Information on drive parts. E

  31 DISK – second drive ID copy E

  14 STRS E

  35 AT_XAL E

  46 OPTI – self-testing settings. E

  47 STRS E

  48 Information on drive parts. E

  Codes of the ?Importance? column in Table 2:

  A – essential and must have version corresponding to the specific head-and-disk assembly;

  B – yes, necessary, but can be replaced with one from another drive;

  C – yes, necessary, but partial module corruption does not prevent drive from starting;

  D – without one the drive starts normally but considerably slower than a totally operational drive;

  E